Allegion: Fire safety in school design reported by RIBA

A modern office training room with employees participating in online course - Health and Safety Buyer

Share this article:

Allegion: Fire safety in school design reported by RIBA

“Dangerous and dilapidated”, “wasteful” “school buildings are failing our children and teachers”. A damning report from RIBA on the UK’s school building stock, but what can be done to rectify the situation from a door hardware perspective?

A recent report by RIBA, titled Better Spaces for Learning, has revealed some disappointing facts on the UK’s school buildings situation. Key revelations included:

• One in five teachers have considered quitting because of the wretched condition of the school buildings they have to teach in

• Over-engineered schools, with Government-specified equipment that only costly consultants know how to operate, is costing £150 million per year which could have been avoided if schools were designed better

• The Government’s Education Funding Agency’s new school building programme is too rigid and is leading to waste and poor value for tax payers

RIBA has also identified that a school that has been designed well can reduce running and maintenance costs, while also encouraging good behaviour of pupils and increasing the level of safety in the building.

One very crucial element to make with school design is the consideration of fire safety, and how best to protect pupils, teachers and the wider community. Statistics show that the fire service are called out to more than 2,000 schools in the UK to put out a fire, ranging from small rubbish fires to larger more damaging fires that seriously affect the operation of the school.

Regrettably, many fires in schools are started deliberately, and also alarmingly during school time. Therefore, focusing on achieving the highest level of safety and knowing what needs to be done within the property to ensure fire is managed effectively and safely is paramount to reducing disruption times, stopping schools from burning down and preventing a loss of life.

Escape routes

Escape routes are vital to every building, especially schools. There will normally be one or two alternative short escape routes, leading to the final exit door or a door to a protected stairway.

Escape routes need to have fire resistant walls and ceilings, and fire doors should be fitted to stop the spread of fire. Routes need to be regularly checked to ensure that they are not obstructed, and that fire exit doors are unlocked and operate correctly.

Other common problems to look out for are: broken door closers, damaged fire doors, missing or damaged ceiling tiles.

Fire doors

Never prop or wedge open

Fire doors can meet all required standards and be entirely suitable on paper, but once a building is ready for occupancy, fire doors will only serve their purpose if they are used correctly.

For example, fire doors should never ever be propped or wedged open. This is an extremely dangerous thing to do as a fire door made from heavy duty and specially engineered materials and is sealed accordingly to prevent the spread of fire, but it does not work if the door is being held open. Perhaps users of the buildings feel that propping open a fire door gives means of a quicker escape, or facilitates the movement of high volumes of pupils through a corridor, but realistically all this may end up doing is causing much more detrimental damage should a fire spread further than necessary.

Quality over quantity

A manual door closer designed to work in more extreme situations like a school, if correctly specified and fitted from the outset, will more than pay for itself in a few years and will ensure that fire doors are kept closed and open easily throughout the designed life cycle of the building. They will also help to protect the frame and the hinges and even surrounding walls. Quality door component manufacturers have closers that are tested to 10,000,000 cycles which would equate to a door that opens 500,000 times a year for 20 years.

On the flip side, the money and time on labour spent replacing a lower quality product will leave the authority or school far worser off financially, without even considering replacing the door from the countless times it gets damaged or fixing holes from screws.

Using a fire door check list to ensure your doors and door hardware meet requirements is a good way to make sure your fire doors are legal and safe.

Electromechanical solutions

A good alternative to wedging doors open is to use door closers that link with an electro-magnetic hold open system to the fire alarm. If there is a fire and the fire alarm activates, the system automatically releases the doors and let them shut. Alternatively, a free-swinging electro-magnetic door closer linked to the fire detection system will facilitate a barrier free operation to the door, whilst still allowing the door to be manually closed if required, such as a class room door.

Final exit doors are often fitted with panic exit devices to provide safe and effective escape through the doorway with minimum effort, and without prior knowledge of operation. In many schools it is often the case that entrance doors will also be one of the fire exits for the building, which brings the security of the building into question. Security measures should never compromise the ability of occupants to escape from the building.

An electromechanical panic exit device such as the Briton 571 EL could be considered. It works like a normal exit device, instantly opening to allow immediate exit, but it can be integrated with access control systems which means that outside access can be gained by either using a remote button or local keypad, without comprising security or the safety of pupils and staff in the event of a fire.

Ongoing assessments and maintenance

In local authority schools responsibility for fire safety is usually shared between the authority and the headteacher. Between them, they are responsible for meeting all relevant building standards, including the installation and maintenance of fire alarm systems, and the ongoing compliance with fire safety legislation and fire safety management within the school. In independent schools, responsibility generally rests with the owner of the building.

The headteacher, proprietor or other staff members who are responsible for the building users’ safety are required to perform regular fire safety and risk assessments. The main duties include:

• Ensure necessary persons are trained on fire safety
• Conduct fire safety inspections such as ensuring escape routes are clear and fire exit doors are unlocked from the inside
• Ensure firefighting equipment meets regulations
• Check fire alarms and smoke detectors work correctly and effectively

You can visit the UK’s official government website for more information about fire safety risk assessments in educational premises.

For further information about door hardware and fire safety products within schools, call Allegion’s specification team 0121 380 2400. Allegion also offer a Try Me & Keep Me Programme, where expert advice on the right door closers for your application is offered and fitted for free.

[su_button url=”http://www.allegion.com/corp/en/index.html” target=”blank” style=”flat” background=”#df2027″ color=”#ffffff” size=”10″ radius=”0″ icon=”icon: arrow-circle-right”]Click here to find out more about Allegion[/su_button]

About International Health & Safety Buyer

Health & Safety Buyer is the premier global voice of the health and safety industry, providing expert coverage, in-depth features, exclusive interviews, and valuable insights across print, digital, and event platforms. Published 6 times a year, the magazine is a trusted source for professionals looking to stay informed on the latest innovations, trends, and business developments in the health and safety sector.

To contribute an article or explore sponsorship opportunities, please get in touch with our team below.

Katie Tracy picture

Katie Tracy

Editor

Chris Lingham picture

Chris Lingham

Group Sales Manager

Afua Akoto Picture

Afua Akoto

Marketing Manager

Related News

National Safety Council_logo_Health&SafetyBuyer.com

NSC expands safety technology investment calculators

The National Safety Council’s has expanded its Employer Investment Calculators to help employers enhance workplace safety
Research reveals insights on ladder safety and the ways in which tailored practices can enhance the wellbeing of all workers. healthandsafetybuyer.com

Research highlights ladder safety risks for women

Research reveals insights on ladder safety and the ways in which tailored practices can enhance the wellbeing of all workers
The ILO's outlines its project in Türkiye aimed at enhancing workplace compliance and support for labour inspectors and employers. healthandsafetybuyer.com

ILO project strengthens workplace compliance

The ILO’s outlines its project in Türkiye aimed at enhancing workplace compliance and support for labour inspectors and employers
HSE-Logo - Health&SafetyBuyer.com

Scaffolding company fined after worker death

A scaffolding company has been fined £16,000 following the death of a trainee scaffolder who fell five metres
The HSA in Ireland has held a conference addressing the risks of carcinogenic substances in the workplace. healthandsafetybuyer.com

Company fined following fatal delivery truck incident

Kavanagh Retailing fined €125,000 after a fatal incident involving a delivery truck at SuperValu in County Mayo
 Ari Fatah, Technical Standards Manager at Veriforce CHAS. healthandsafetybuyer.com

Report reveals gaps in construction safety policies

VeriforceCHAS reveals its research on construction safety policies and their discrepancies in actual working practices in the industry
Safety Shield Global. healthandsafetybuyer.com

Safety Shield Global highlights AI in construction

Safety Shield Global’s AI-driven safety measures can enhance detection accuracy and prevent accidents effectively
ASSP. healthandsafetybuyer.com

Virginia launches workplace safety video contest

The Virginia workplace safety competition encourages young workers to create videos that promote awareness and rights at work
Over 11,000 attendees visited the NSC Safety Congress in Indianapolis to experience the latest in workplace safety innovations. healthandsafetybuyer.com

NSC Safety event attracts more than 11,000 attendees

Over 11,000 attendees visited the NSC Safety Congress in Indianapolis to experience the latest in workplace safety innovations
Scroll to Top